Calculate & estimate

Malaysia solar & battery sizing

Turn your energizer’s continuous power draw into practical battery, panel and controller sizes for Malaysian weather.

W

Use average continuous consumption—not energizer output joules.

The selected chemistry drives the main battery recommendation.

Advanced assumptionsMalaysia defaults

Default 12V

Malaysia: 3.5h

Heat, wiring and controller losses

Malaysia standard: 3 days

144Wh used each day

Continuous 6W · 0.5A at 12V · 3.5 peak sun hours · 75% system efficiency

3 days autonomy

Malaysia recommended

Pang choice
80AhAGM @ 12V

Formula result 72Ah · rounded upward to a practical size

Daily-balance minimum
60W panel
Installed panel target
80W
Charge controller
10A
Flooded lead-acid alternative
80Ah
LiFePO4 alternative
50Ah

Three rainy-day reserves plus 25% more panel capacity for recovery after cloudy weather.

Raw solar minimum: 54.9W · recovery multiplier ×1.25

2 days autonomy

Minimum

50AhAGM @ 12V

Formula result 48Ah · rounded upward to a practical size

Daily-balance minimum
60W panel
Installed panel target
60W
Charge controller
10A
Flooded lead-acid alternative
50Ah
LiFePO4 alternative
35Ah

Covers normal daily use with two days of battery autonomy. Best for a clear, unshaded site.

Raw solar minimum: 54.9W · recovery multiplier ×1

5 days autonomy

Extended rain

120AhAGM @ 12V

Formula result 120Ah · rounded upward to a practical size

Daily-balance minimum
60W panel
Installed panel target
120W
Charge controller
20A
Flooded lead-acid alternative
120Ah
LiFePO4 alternative
80Ah

Five days of reserve and double the daily-balance panel target for difficult or remote sites.

Raw solar minimum: 54.9W · recovery multiplier ×2

Assumptions: Assumes 3.5 peak sun hours, 75% system efficiency, 12V DC, 50% usable AGM capacity, and 25% controller current headroom. Shading, panel direction, long cable runs, dirt and local weather can require more capacity. Confirm panel Voc/Isc and controller limits with the equipment manufacturer before installation.

Solar versus mains cost

Optional ownership estimate using the AGM selection above.

Enter the solar system cost to compare ownership against mains electricity.